Topic:  Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite (BRIMM) Study

Overview:

Monoexponential apparent diffusion coefficient (ADC) and biexponential intravoxel incoherent motion (IVIM) analysis of diffusion-weighted imaging (DWI) is helpful in the characterization of breast tumors. However, repeatability and reproducibility studies across scanners and across sites are scarce. Therefore, the purpose of this study is to evaluate the repeatability and reproducibility of ADC and IVIM parameters (tissue diffusivity (Dt), perfusion fraction (fp) and pseudo-diffusion (Dp)) within and across sites employing MRI scanners from different vendors in a customized breast diffusion phantom (built in collaboration with CaliberMRI). The studies were performed twice in each of two scanners (different vendors and institutions), on each of 2 days, resulting in four studies per scanner. A bipolar gradient twice-refocused spin echo sequence and monopolar gradient single spin echo sequence at 3 T were used in the two scanners. ADCs of the polyvinylpyrrolidone (PVP) and water were compared with the vendor-calibrated values at the temperature indicated by the in situ liquid crystal thermometer.

ADC and IVIM repeatability and reproducibility within and across sites were estimated via the within-system coefficient of variation (wCV). Pearson correlation coefficient (r) was also computed between IVIM metrics and flow speed. ADC and Dt demonstrated excellent repeatability and reproducibility at the two sites. fp and Dp exhibited good and moderate reproducibility. fp and Dt demonstrated high correlations with flow speed while Dp showed lower correlations. fp correlations with flow speed were significant at both sites. IVIM results were reproducible within both sites, and a progressive trend towards reproducibility across sites except for fp, which may have been impacted by different gradient waveforms.

Presenters:

Dr. Eric Sigmund is a Professor in the Department of Radiology at NYU Grossman School of Medicine. Prof. Sigmund’s group actively researches advanced diffusion MRI applications throughout the body, including intravoxel incoherent motion (IVIM), diffusion tensor imaging (DTI), and diffusion kurtosis imaging (DKI) in a range of applications (especially oncologic imaging in breast and kidney, renal function).

Dr. Basukala is a postdoctoral fellow in the Department of Radiology at NYU Grossman School of Medicine working with Dr. Sigmund. He has worked on evaluation and translation of intravoxel incoherent motion (IVIM) for characterization of breast cancer malignancy and prediction of treatment response. He has experience in biomedical imaging, phantoms and retrospective multicenter and multivendor breast cancer studies using multiple software platforms including deep learning.

Recent papers by Drs. Sigmund and Basukala

Multisite MRI Intravoxel Incoherent Motion Repeatability and Reproducibility across 3 T Scanners in a Breast Diffusion Phantom: A BReast Intravoxel Incoherent Motion Multisite (BRIMM) Study

Motion and Flow Robust Free-Breathing Diffusion Kurtosis Imaging of the Kidney

Evaluating Breast Cancer Intravoxel Incoherent Motion MRI Biomarkers across Software Platform

Cardiac gated diffusion-weighted MR imaging assessment of kidney function in kidney cancer patients

Related Articles

2025 User Group Session Calendar!

We are excited to share our 2025 User Group Sessions!  Mark your calendars: SESSION 1: Tuesday, April 1st, 9:00 a.m. MDT Topic: Annual Physics Testing with the CaliberMRI Mini Hybrid Phantom. Guest Speaker: Norman P. Sipp, MS DABR, Chief Diagnostic Medical Physicist: Ascension Seton Network-Austin, TX SESSION 2: Tuesday, June 24th, 9:00 a.m. MDT Topic: […]

Open Office Hours – Every Tuesday 9-10 a.m. MDT!

Join us for open office hours! Ask questions about your phantom, qCal-MR and meet others advancing quantitative MRI!

Join Us at RSNA – Booth 7610 – North Hall Level 3

Heading to RSNA?  We’ll be exhibiting at Booth 7610 (North Hall Level 3) and would love to discuss QA/QC, AI/ML/DL testing and validation, R&D, and/or custom solutions.  Our cloud-based software, qCal-MR, now supports more than 45 scanner makes and models on Canon, GEHC, Hyperfine, Philips, Siemens, and United Imaging Scanners.  We’ll be showcasing our new products, and are available to discuss collaborations.  Reach out if you’d like to set up a meeting.

CaliberMRI announces release of the qDisc, a new quantitative MRI phantom for added functionality of the Medium ACR Phantom

BOULDER, Colo., Nov. 26, 2025 /PRNewswire/ — CaliberMRI, an industry leader in standardizing Magnetic Resonance Imaging (MRI), announced the release of a new quantitative MRI phantom compatible with the Medium ACR phantom. CaliberMRI’s qDisc (quantitative Dual Imaging Standardization Compartment) Model 141 allows sites to baseline T1, T2, ADC, and Proton Density in a single slice when scanning the Medium ACR phantom. The qDisc includes the Company’s patented MR readable LC Thermometer and is supported by qCal-MR®, an automated QA/QC analysis software. “This offering provides a practical option for gathering important quantitative metrics during routine scans with an ACR phantom,” says William Hollander, CEO of CaliberMRI. “With the rise of quantitative MRI offerings, the qDisc can be used as a first step toward harmonization of MRI scanners and AI software for analysis”. Hollander added. This phantom is intended to complement CaliberMRI’s more complete phantom platform solutions.

Great Reading For ASTRO!

Are you heading to ASTRO next week?  If so, take a look at some incredible articles below (some hot off the press!).  Please reach out directly to authors on their work or to CaliberMRI on our phantoms.  If you’d like to set up a meeting at ASTRO, please reach out to us directly at info@qmri.com. […]

Happy 75th Birthday to our CEO and Founder, Bill Hollander

Happy 75th Birthday to our CEO and founder Bill Hollander! A scientific instrument maker, Bill started his career at JILA in 1979 (a joint institute between National Institute of Standards and Technology (NIST) and University of Colorado Boulder). 

Join us at ISMRM – Booth C15

Advancing Quantitative MRI! Stop by to visit our Booth (C19) at ISMRM to talk about data quality, standardization, reproducibility, and quantitative imaging in the age of AI. Topics: clinical trials, QA/QC, R&D, and AI/ML validation/testing.

Article Word Cloud!

Take a look at our word cloud: qMRI, imaging, diffusion, T1, T2 ADC Mapping! Reproduciblity! QA/QC! Repeatability, Reproducibility, QA/QC!

APS Session – Multiparametric Tissue Mimics for Breast Imaging and Medical Device Testing

Multiparametric Tissue Mimics for Breast Imaging and Medical Device Testing
Stephen Russek, Todor Karaulanov (presenter), Willaim Hollander, Chamni Jayarathna, Callie Weiant, John Wenzel, Shannon John

We present our work on developing anatomically realistic, quantitative multiparametric MRI (qMRI) phantoms designed to standardize imaging of both healthy and diseased breast tissue. The lack of standardized, morphology-accurate phantoms currently limits the effectiveness of qMRI in both clinical and research settings. Without realistic tissue-mimicking models, radiologists, technologists, and researchers face challenges in learning optimal acquisition protocols and interpreting quantitative data.

2025 – a year in review – 60 papers and hundreds of authors advancing qMRI

Looking back to 2025, we want to thank the hundreds of customers and collaborators who authored more than 60 papers, talks, and abstracts using CaliberMRI phantoms. Products cited include: (1) Relaxometry phantoms (T1, T2, PD) – National Institute of Standards and Technology (NIST)/ISMRM Model 130 (as well as Models 136 and 106) (2) Diffusion phantom […]

CaliberMRI User Group Session 2 – June – The variability of Mean ADC Measurements with Simultaneous Multi-slice Imaging in a NIST/QIBA/CaliberMRI Diffusion Phantom

Join us for Session 2:  Tuesday, June 24th, 9:00 AM (MDT).  To sign up or for login details, please email info[at]qmri.com.
Topic: The variability of Mean ADC Measurements with Simultaneous Multi-slice Imaging in a NIST/QIBA/CaliberMRI Diffusion Phantom
Guest Speakers: Dr. Ryckie Wade, PhD, and Matthew Marzetti, MsC, University of Leeds, United Kingdom

Upcoming User Group Sessions – Join Us!

Please join us for our upcoming user group sessions! We’ll be discussing MR-Linac, Diffusion, Repeatability, and Relaxometry.